The Sysmex CS-5100 system is a high throughput, best in class coagulation analyser with the added advantage of automated pre-analytical sample quality check to maximise the benefit of integrating coagulation testing into the LAS (laboratory automated transport system). This fulfils customers’ needs for both speed and quality.
CS-5100
High volume, fully automated, wagon-mounted haemostasis that is compatible with laboratory automated transport systems.
The CS-5100 system addresses the need of high-volume laboratories with its optimised throughput including full random access loading. It utilises Sysmex proprietary multi-wavelength analysis technology to deliver the high-quality results and provide extra safety to patient results via pre-analytical sample check. The advanced technology consolidates both routine and speciality haemostasis testing in a single analyser.
Exceptional productivity and efficiency
High quality results and extra safety
This onboard pre-analytical check further streamlines the sample handling process on LAS.
New standard in haemostasis testing
1. Shima M, Thachil J, Nair SC, Srivastava A.Towards standardization of clot waveform analysis and recommendations for its clinical applications. J Thromb Hemost. 2013; 11:1417-20
Detection principles | Multi-wavelength detector for transmitted light at 340, 405, 575, 660 and 800 nm |
Detection channel/method | 20 channels for clotting, chromogenic and immunoassays (8 of these channels are also be used for platelet aggregation assays) |
Parameters | up to 60 parameters can be analysed simultaneously |
Throughput | PT: 400 tests/h PT/APTT: 400 tests/h |
Sampling | Continuous loading of maximum 10 racks of 10 tubes each, cap-piercing functionality 5 dedicated STAT positionsDirect sampling via left side of the analyser when connected to an optional Sysmex haemostasis island transportation system or other laboratory automation track system |
Reagent holder | 40 tilted reagent vial positions (10°C), 10 with mixing function 5 positions (room temperature) All positions with positive reagent identification |
Reference curves | Maximum 10 reference curves per lot Maximum 10 lots per parameter Maximum 250 parameters |
Quality control | X-bar control, Levy-Jennings control Multi-rule (Westgard Rule) monitoring 750 files with maximum 1,200 data points each |
Data storage | Up to 10,000 sample results with reaction curves |
Printer | Graphic or Data Printer (optional) |
Dimensions (WxHxD)/weights | Main unit: 1,030 × 1,280 × 1,150 mm, 278 kg (approximate)Pneumatic unit: 280 × 400 × 355 mm, 17 kg (approximate) |
- Features & Benefits
-
The CS-5100 system addresses the need of high-volume laboratories with its optimised throughput including full random access loading. It utilises Sysmex proprietary multi-wavelength analysis technology to deliver the high-quality results and provide extra safety to patient results via pre-analytical sample check. The advanced technology consolidates both routine and speciality haemostasis testing in a single analyser.
Exceptional productivity and efficiency
High quality results and extra safety
This onboard pre-analytical check further streamlines the sample handling process on LAS.
New standard in haemostasis testing
1. Shima M, Thachil J, Nair SC, Srivastava A.Towards standardization of clot waveform analysis and recommendations for its clinical applications. J Thromb Hemost. 2013; 11:1417-20
- Assay
-
- Specifications
-
Detection principles Multi-wavelength detector for transmitted light at 340, 405, 575, 660 and 800 nm Detection channel/method 20 channels for clotting, chromogenic and immunoassays (8 of these channels are also be used for platelet aggregation assays) Parameters up to 60 parameters can be analysed simultaneously Throughput PT: 400 tests/h
PT/APTT: 400 tests/hSampling Continuous loading of maximum 10 racks of 10 tubes each, cap-piercing functionality
5 dedicated STAT positionsDirect sampling via left side of the analyser when connected to an optional Sysmex haemostasis island transportation system or other laboratory automation track systemReagent holder 40 tilted reagent vial positions (10°C), 10 with mixing function
5 positions (room temperature)
All positions with positive reagent identificationReference curves Maximum 10 reference curves per lot
Maximum 10 lots per parameter
Maximum 250 parametersQuality control X-bar control, Levy-Jennings control
Multi-rule (Westgard Rule) monitoring
750 files with maximum 1,200 data points eachData storage Up to 10,000 sample results with reaction curves Printer Graphic or Data Printer (optional) Dimensions (WxHxD)/weights Main unit:
1,030 × 1,280 × 1,150 mm, 278 kg (approximate)Pneumatic unit: