CellTrics

Add to wishlist
Category:

CellTrics are the perfect tool for preparation of sample suspension from tissue, fluids, plant material, nuclei etc.

CellTrics

CellTrics are innovative cell strainers for a rapid sample preparation with an extreme high flow rate and a patented ventilation hole. They are suitable for use in cell culture or measurement by flow cytometry. These cell strainers fit on tubes of different diameters.CellTrics are the perfect tool for preparation of sample suspension from tissue, fluids, plant material, nuclei etc.

Available in non-sterile and sterile packaging. Mesh from 5µm to 150µm.

Features & Benefits

CellTrics are innovative cell strainers for a rapid sample preparation with an extreme high flow rate and a patented ventilation hole. They are suitable for use in cell culture or measurement by flow cytometry. These cell strainers fit on tubes of different diameters.CellTrics are the perfect tool for preparation of sample suspension from tissue, fluids, plant material, nuclei etc.

Available in non-sterile and sterile packaging. Mesh from 5µm to 150µm.

Dimensions / weights
  • W x H x D [mm / kg]
  • XN-450: 450 x 440 x 460 / approx. 35 kg
Throughput
  • CBC + DIFF: up to 70 samples/hour
  • CBC + DIFF + RET: up to 35 samples/hour
  • Body fluide mode: up to 30 samples/hour
Aspiration volume
  • 25 µL in WB / Low WBC mode,
  • 70 µL in PD and BF mode
Analysis parameters
  • Whole Blood
    WBC, RBC, HGB, HCT, MCV, MCH, MCHC, PLT, RDW-SD, RDW-CV, PDW, MPV, P-LCR, PCT, NEUT#, LYMPH#, MONO#, EO#, BASO#, NEUT%, LYMPH%, MONO%, EO%, BASO%, IG#, IG%
  • With RET (optional)
    RET#, RET%, IRF, LFR, MFR, HFR, RET-He, PLT-O, IPF#, IPF, RBC-He, Delta-He, HYPO-He, HYPER-He
  • Body Fluids (optional)
    WBC-BF, RBC-BF, MN#, PMN#, MN%, PMN%, TC-BF#
Measurement principles
  • WBC DIFF/RET: Fluorescence Flow Cytometry
  • WBC: Flow Cytometry
  • RBC/PLT: DC Impedance method with hydrodynamic
  • focussing
  • HGB: Cyanide-free SLS method
Data storage capacities
  • Results: 100,000 samples
  • Patient information: 10,000 records
  • Calibration history: 20 times/ module
  • QC files: 99 files including XbarM
  • QC plots: 300 plots / file
User maintenance
  • Daily shutdown
  • Weekly cleaning sequence with Cellclean or Cellclean Auto
Image

The tittle of the video in brief

More Information

Features & Benefits

CellTrics are innovative cell strainers for a rapid sample preparation with an extreme high flow rate and a patented ventilation hole. They are suitable for use in cell culture or measurement by flow cytometry. These cell strainers fit on tubes of different diameters.CellTrics are the perfect tool for preparation of sample suspension from tissue, fluids, plant material, nuclei etc.

Available in non-sterile and sterile packaging. Mesh from 5µm to 150µm.

Specification
Dimensions / weights
  • W x H x D [mm / kg]
  • XN-450: 450 x 440 x 460 / approx. 35 kg
Throughput
  • CBC + DIFF: up to 70 samples/hour
  • CBC + DIFF + RET: up to 35 samples/hour
  • Body fluide mode: up to 30 samples/hour
Aspiration volume
  • 25 µL in WB / Low WBC mode,
  • 70 µL in PD and BF mode
Analysis parameters
  • Whole Blood
    WBC, RBC, HGB, HCT, MCV, MCH, MCHC, PLT, RDW-SD, RDW-CV, PDW, MPV, P-LCR, PCT, NEUT#, LYMPH#, MONO#, EO#, BASO#, NEUT%, LYMPH%, MONO%, EO%, BASO%, IG#, IG%
  • With RET (optional)
    RET#, RET%, IRF, LFR, MFR, HFR, RET-He, PLT-O, IPF#, IPF, RBC-He, Delta-He, HYPO-He, HYPER-He
  • Body Fluids (optional)
    WBC-BF, RBC-BF, MN#, PMN#, MN%, PMN%, TC-BF#
Measurement principles
  • WBC DIFF/RET: Fluorescence Flow Cytometry
  • WBC: Flow Cytometry
  • RBC/PLT: DC Impedance method with hydrodynamic
  • focussing
  • HGB: Cyanide-free SLS method
Data storage capacities
  • Results: 100,000 samples
  • Patient information: 10,000 records
  • Calibration history: 20 times/ module
  • QC files: 99 files including XbarM
  • QC plots: 300 plots / file
User maintenance
  • Daily shutdown
  • Weekly cleaning sequence with Cellclean or Cellclean Auto
Video
Image

The tittle of the video in brief

Documents